x
TEC CRO Logo

    Book Now

    • Mumbai, India
    • +91 8655915188
    • info@teccro.org
    TEC CRO Logo
    • info@teccro.org
    • Mumbai, India
    • Contact Us
    • Home
    • About Us
      • Who We Are
      • Our Team
      • Expertise
      • Visual Compendium
      • Journal Articles
    • Our Services
      • Clinical Operations
      • Data Management
      • Regulatory Affairs
      • Biostatistics
      • Medical Writing
      • Institutional Ethics Committee
      • Site Management Organization
    • Insights
      • Expert Trial
      • Intellectual Property Rights
      • Expert Advisory Panel
      • Press Release
      • Joint Initiative
    • More
      • Blog
      • Faq’s
      • Events
      • Unveil TECCRO
    • Contact Us
    Logo

    Contact Info

    • 201, Navratnamala Cooperative Housing Society Limited, First Floor Cts No 6946 , Cst Road, Back Side Of, Bandra Kurla Complex, Santacruz East, Mumbai, Maharashtra 400098
    • +91 7028065165
    • info@teccro.org

    In Vivo Intraocular Distribution and Safety of Periocular Nanoparticle Carboplatin for Treatment of Advanced Retinoblastoma in Humans

      TECCRO > In Vivo Intraocular Distribution and Safety of Periocular Nanoparticle Carboplatin for Treatment of Advanced Retinoblastoma in Humans

    Abstract

    Purpose

    To study the intraocular distribution and safety of polymethylmethacrylate nanoparticles loaded with carboplatin after posterior subtenon injection in humans.

    Design

    Prospective, interventional, comparative case series.

    Methods

    Six patients (mean age: 26.83 ± 7.5 years), scheduled to undergo planned uniocular enucleation in an institutional setting, were randomly divided into 3 groups. Each group received a 10 mg/mL posterior subtenon injection of nanoparticle carboplatin in the eye to be enucleated. Two eyes were enucleated 6, 24 and 72 hours post injection. Intravenous blood was collected during enucleation. The concentration of carboplatin reaching various intraocular tissues was determined by inductively coupled plasma atomic emission spectroscopy. The drug toxicity in the ocular tissues was assessed by histopathology and high-resolution transmission electron microscopy.

    Results

    The highest level of carboplatin was detected in retinas (8.33 ± 1.69 mg/g), up to 24 hours post treatment. The intravitreal concentration continued to increase gradually until 72 hours (3.46 ± 0.26 mg/g). The choroids and lenses showed very low levels of carboplatin after 6 hours, with negligible amounts at 72 hours. No signs of tissue damage were observed on histopathology or electron microscopy. Intravenous concentration of carboplatin was undetectable in all patients.

    Conclusion

    Results may indicate an increased facilitated trans-scleral transport of nanoparticle carboplatin, with a sustained-release behavior but without any associated short-term ocular or systemic side effects in humans. The very high concentrations achieved in vitreous and retina after a single posterior subtenon injection may be clinically useful for adjunctive treatment of advanced intraocular retinoblastoma with vitreous seeds. However, further studies are needed to assess long-term toxicity and clinical efficacy.

     

    Know More

    TEC CRO Logo

    Reach Us:

    • 1st-3rd Floor, Navratnamala Cooperative Housing Society Ltd, CTS No. 6946, Backside of Bandra Kurla Complex, Santacruz (East), Mumbai-400098
    • +91 8655915188
    • info@teccro.org

    Latest Events

    Site Initiation Visit at TECCRO | Advancing Aesthetic Research
    22 May, 2025
    International Conference on Biomedical and Applied Clinical Sciences (BioMACS)
    25 Feb, 2025
    TECCRO’s International Debut at American Academy of Cosmetic Surgery (AACS) at La Quinta, Palm Spring, California
    19 Feb, 2025

    Our Services

    • Clinical Operations
    • Data Management
    • Regulatory Affairs
    • Biostatistics
    • Medical Writing
    • IEC/ IRB
    • SMO

    Useful Links

    • About TECCRO
    • Our Team
    • Latest Blog
    • Photo Gallery
    • Contact Us

    TECCRO © 2024 All Right Reserved